Vapor Pressure Deficit (VPD) Calculator
Works out the vapor pressure deficit (VPD) that drives transpiration in a greenhouse, grow tent or field crop: the gap between the water vapor pressure inside the leaf, taken as saturated at leaf temperature, and the vapor pressure of the surrounding air. Describe the air with relative humidity and air temperature, with a dew point reading, or with dry- and wet-bulb psychrometer temperatures. Add the canopy temperature from an infrared thermometer for leaf VPD, or leave it out to get the VPD of the air alone. Results come in kPa, mbar or psi, with the dew point and relative humidity that match your readings.
- The air inside the leaf is saturated at leaf temperature, and vapor pressure over liquid water is used even below 0 °C (no ice correction).
- Readings are taken at the same time and place, near the canopy. A single reading gives the VPD at that moment, not a daily average.
- Ideal VPD ranges depend on the crop, growth stage and light level; the calculator reports the deficit but does not judge whether it suits a particular crop.
Formula
- The air inside the leaf is taken as saturated, so the leaf vapor pressure is simply e°(T) at leaf temperature. Without a leaf reading, the leaf is assumed to be at air temperature and the result is the VPD of the air: e°(T_air) × (1 − RH/100).
- With a dew point, e_a = e°(T_dew), because air cooled to its dew point is saturated without its moisture content changing. The air temperature is then only needed when the leaf temperature is unknown.
- With a psychrometer, e_a = e°(T_wet) − a_psy × P × (T_dry − T_wet) (FAO-56 eq. 15–16), where a_psy is 0.000662 °C⁻¹ for an aspirated instrument, 0.000800 for natural ventilation and 0.001200 for an indoor, non-ventilated one, and P is the atmospheric pressure in kPa.
- The Tetens equation is accurate to about 0.1% between 0 and 50 °C; inputs from −50 to 60 °C are accepted. 1 kPa = 10 mbar (hPa) = 0.145038 psi. Vapor pressures are shown to 3 decimals in kPa, 2 in mbar and 4 in psi.
- Dew point and relative humidity outputs come from the same Tetens equation solved backwards, so they stay consistent with the VPD shown.
Greenhouse at 22 °C and 55% RH with a 20 °C canopy
- Do you know the canopy (leaf) temperature?: yes
- Describe the air with: rh
- Temperature unit: C
- Pressure unit: kPa
- Air temperature (dry bulb): 22 °C
- Relative humidity: 55 %
- Dew point: 12 °C
- Wet-bulb temperature: 16 °C
- Atmospheric pressure: 101.3 kPa
- Psychrometer type: aspirated
- Leaf (canopy) temperature: 20 °C
The leaf at 20 °C holds saturated vapor at e°(20) = 0.61078 × exp(17.27 × 20 ÷ 257.3) = 2.338 kPa. The air at 22 °C could hold e°(22) = 2.644 kPa but is only 55% saturated, so its vapor pressure is 2.644 × 0.55 = 1.454 kPa. The leaf VPD is 2.338 − 1.454 = 0.884 kPa (8.84 mbar), and the air's dew point is 12.5 °C.