Cell Dilution Calculator

Stock suspension
Cell density of the suspension you start from, e.g. from a hemocytometer count. Scientific notation such as 2.5e6 works.
Diluted suspension
Total volume after adding medium or buffer (stock + diluent).
Biology Updated 29 Oct 2026

Plan a cell suspension dilution with C1 × V1 = C2 × V2. Enter any three of the stock concentration, the volume of stock to take, the target concentration and the final volume, each with its own unit (µL, mL, cL or L), and the calculator finds the fourth. It also reports the dilution factor, how much medium or buffer to add, the total number of cells, and a serial dilution plan when the stock volume is too small to pipette accurately.

  • Cells are evenly suspended when the stock is sampled, and no cells are lost to tube walls or pipette tips.
  • Volumes are additive: the final volume equals the stock volume plus the diluent volume.
  • C1 and C2 count the same population (e.g. viable cells only).

Formula

C1 × V1 = C2 × V2. V1 = C2 × V2 ÷ C1; C1 = C2 × V2 ÷ V1; C2 = C1 × V1 ÷ V2; V2 = C1 × V1 ÷ C2. Dilution factor = C1 ÷ C2 = V2 ÷ V1; diluent = V2 − V1
  • C1 is the stock (initial) concentration, V1 the volume of stock you pipette, C2 the target concentration and V2 the total final volume including the diluent.
  • Every value is converted to cells/mL and mL before solving, so each field can use its own unit (1 cells/µL = 1,000 cells/mL; 1 cL = 10 mL; 1 L = 1,000 mL).
  • The dilution factor 1:X means one part stock in X parts final suspension; the stock-to-diluent ratio is therefore 1 : (X − 1).
  • When V1 falls below 10 µL the calculator proposes pre-dilutions of 1:100 (10 µL into 990 µL) or 1:10 (100 µL into 900 µL) until the final transfer is at least 10 µL. A plan is only drawn up when the final volume is at least 100 µL; for smaller volumes it simply advises pre-diluting the stock.

Seeding suspension at 2 × 10⁵ cells/mL from a 2.5 × 10⁶ cells/mL stock

Inputs
  • Calculate: v1
  • Initial concentration, C1: 2500000
  • Unit: ml
  • Volume of stock to take, V1: 0.8
  • Unit: ml
  • Final concentration, C2: 200000
  • Unit: ml
  • Final volume, V2: 10
  • Unit: ml

V1 = C2 × V2 ÷ C1 = 200,000 × 10 ÷ 2,500,000 = 0.8 mL. Add 10 − 0.8 = 9.2 mL of medium to 0.8 mL of the stock. The dilution factor is 2,500,000 ÷ 200,000 = 1:12.5 and the tube holds 2 × 10⁶ cells in total.

Sources & references

Frequently asked questions

How do I calculate how much cell suspension to add?
Rearrange C1 × V1 = C2 × V2 to V1 = C2 × V2 ÷ C1. For example, to make 10 mL at 2 × 10⁵ cells/mL from a stock of 2.5 × 10⁶ cells/mL, take 0.8 mL of stock and top it up to 10 mL with medium (9.2 mL).
What is the dilution factor?
It is the ratio of the final volume to the volume of stock used, V2 ÷ V1, which equals C1 ÷ C2. A 1:10 dilution means 1 part stock in 10 parts total, i.e. 1 part stock plus 9 parts diluent. When you count a diluted sample, multiply the count by the dilution factor to get the stock concentration.
When should I use a serial dilution?
When the stock volume you would need is too small to pipette accurately, typically below a few microlitres. Diluting in steps (for example 1:100 then 1:100 again) keeps every transfer in a reliable range. To go from 10⁷ to 100 cells/mL (a 1:100,000 dilution) in 1 mL you can do two 1:100 steps to reach 1,000 cells/mL, then add 100 µL of that to 900 µL.
Can I use it for seeding a plate?
Yes. Multiply the cells you want per well by the number of wells (plus a little extra) to get the total cells, divide by the volume per well to get C2, and use the total volume as V2. Then solve for V1 from your counted stock concentration.
Why does the calculator say I need to concentrate the cells?
If the target concentration is higher than the stock, no amount of dilution can reach it: V1 would be larger than V2. Spin the cells down and resuspend the pellet in a smaller volume, then recount.

Related calculators

Cell Doubling Time Calculator Work out how long a cell culture takes to double from two measurements of the same growth parameter, such as cell number, cells/mL, confluency or optical density, taken a known time apart. The calculator also gives the exponential growth rate, number of doublings and fold change, and can run the model the other way to predict the final value, the starting value or the time needed from a known doubling time or growth rate. Bacteria Growth Calculator Models exponential bacterial growth with N(t) = N(0) × (1 + r)^t. Solve for the final number of bacteria, the starting number, the elapsed time, or the growth rate and doubling (generation) time from two counts. Give growth either as a per-period growth rate or as a doubling time, choose seconds through years for every time value, and see the number of generations, the fold change, the specific growth rate and a population-over-time table. Log Reduction Calculator Measure how well a disinfectant, sanitizer, heat step or filter kills microbes. Enter the colony forming units (CFU) before and after treatment, each with its own power-of-ten multiplier, to get the log reduction and percent reduction. You can also convert between log and percent reduction, or work out the surviving CFU (or the starting load) needed for a target 3-log, 5-log or 6-log kill. Molarity Calculator Calculates the molarity of a solution, or works backwards to the mass of solute or the volume of solution you need for a target molarity. Molarity is the amount of dissolved substance in moles per litre of solution (mol/L, written M). Enter the molar mass with the mass of solute and the final volume, a target molarity, or a mass concentration in g/L, and get the molarity, moles of solute and concentration.