CO₂ Grow Room Calculator
Works out how much carbon dioxide to release into a grow room, grow tent or small greenhouse to lift it from the current concentration to a target level such as 1,200–1,500 ppm. Enter the room's width, length and height (or its volume) in metric or imperial units and the two CO₂ readings in ppm to get the gas volume in liters, cubic meters and cubic feet, plus its mass from the density of CO₂. Give the time the tank valve stays open to get the regulator flow rate, or give the flow rate to get the time. An optional air-change rate estimates the extra flow needed to hold the target against leakage, and the result flags targets above the 5,000 ppm workplace exposure limit.
- The room is sealed while CO₂ is released and the air is well mixed; plant uptake during the release is ignored.
- Concentrations are ppm by volume; gas volumes and the 1.84 kg/m³ density refer to about 20 °C and 1 atm.
- Safety: 5,000 ppm is the OSHA PEL and NIOSH REL 8-hour exposure limit. Ventilate before entering an enriched room and use a CO₂ monitor; this tool does not replace one.
- The 1,500 ppm plant warning is a general guide; tolerance differs between crops.
Formula
- ppm means parts per million by volume, so raising a room by 1,000 ppm needs 1,000 ÷ 1,000,000 = 0.1% of the room volume as pure CO₂. The CO₂ volume comes out in the same unit as the room volume.
- V_room = width × length × height. Feet, inches and centimeters are converted to meters first; 1 ft³ = 0.0283168 m³ and 1 m³ = 1,000 L.
- Mass uses a CO₂ gas density of 1.84 kg/m³ at 20 °C and 1 atm, the same as Oklahoma State University's figure of 8.7 ft³ per pound. The density is about 1.98 kg/m³ at 0 °C, so a cold room needs about 7% more mass for the same volume.
- The make-up flow assumes outside air enters at the current CO₂ level and the room is well mixed: extra CO₂ per hour = V_room × air changes per hour × (target − current) ÷ 1,000,000.
- Rounding: liters and flow in L/min to 2 decimals, m³ to 4 decimals, ft³ to 3 decimals, grams to 1 decimal.
2 m × 2 m × 2.5 m grow room from 420 to 1,500 ppm in 10 minutes
- Room size from: dims
- Width: 2 m
- Length: 2 m
- Height: 2.5 m
- Length unit: m
- Room volume: 10 m³
- Volume unit: m3
- Current CO₂: 420 ppm
- Target CO₂: 1500 ppm
- Calculate: flow
- Time the valve is open: 10 min
- Time unit: min
- CO₂ flow rate: 1.08 L/min
- Flow unit: lpm
- Air changes per hour (optional): per hour
The room holds 2 × 2 × 2.5 = 10 m³ of air. Raising it by 1,500 − 420 = 1,080 ppm needs 10 × 1,080 ÷ 1,000,000 = 0.0108 m³ = 10.80 L (0.381 ft³) of CO₂, which weighs 0.0108 × 1.84 = 19.9 g. Releasing it over 10 minutes needs a flow rate of 10.80 ÷ 10 = 1.08 L/min, or 0.0648 m³/h = 2.29 ft³/h on a CFH regulator.