Annealing Temperature Calculator

Use the less stable primer, i.e. the one with the lower Tm. Don't know it? Switch to primer sequences above.
Melting temperature of the whole amplified fragment.
Biology Updated 29 Oct 2026

Finds the optimal PCR annealing temperature with the Rychlik formula Ta = 0.3 × Tm(primer) + 0.7 × Tm(product) − 14.9. Enter the melting temperature of the less stable primer and of the PCR product in °C, °F or K, or paste both primer sequences and let the calculator work out each primer's Tm (nearest-neighbour, salt-adjusted or basic method) and the product Tm from its length and GC content at your salt concentration. It also flags primer pairs whose melting temperatures differ by more than 5 °C.

  • Primers match their target perfectly (no mismatches, overhangs or tails).
  • The salt concentration entered is the monovalent cation concentration; Mg²⁺, dNTPs and additives such as DMSO are not modelled.
  • In the nearest-neighbour method the primer is in large excess over its target strand.

Formula

Ta = 0.3 × Tm(primer) + 0.7 × Tm(product) − 14.9, in °C. Product Tm = 81.5 + 16.6 × log₁₀[Na⁺] + 0.41 × %GC − 675 ÷ length. Nearest-neighbour primer Tm = 1000 × ΔH ÷ (ΔS + R × ln Cp) − 273.15
  • Tm(primer) is the melting temperature of the less stable primer of the pair and Tm(product) that of the amplified fragment. This is the empirical equation of Rychlik, Spencer and Rhoads (1990).
  • The constant 14.9 only holds for °C. Values typed in °F or K are first converted to °C (°C = (°F − 32) × 5/9; °C = K − 273.15) and the answer is converted back for display.
  • Product Tm uses the Rychlik formula with [Na⁺] in mol/L, %GC from 0 to 100 and length in base pairs.
  • Nearest-neighbour primer Tm sums the SantaLucia (1998) unified ΔH and ΔS values for each pair of neighbouring bases, adds the initiation terms for the terminal G·C or A·T pairs (and −1.4 cal/(K·mol) for self-complementary primers), corrects the entropy for salt with ΔS + 0.368 × (N − 1) × ln[Na⁺], and uses R = 1.987 cal/(K·mol) with the primer concentration Cp in mol/L, assuming the primer is in large excess over the template.
  • Salt-adjusted primer Tm = 81.5 + 0.41 × %GC − 600 ÷ N + 16.6 × log₁₀[Na⁺]. Basic primer Tm = 2 × (A + T) + 4 × (G + C) below 14 nt, otherwise 64.9 + 41 × (G + C − 16.4) ÷ N.
  • Every Tm formula is an estimate: different methods give answers several degrees apart, and Mg²⁺, dNTPs, DMSO and the polymerase buffer also shift the real value. Treat Ta as a starting point for a gradient PCR.

Worked example: primer Tm 65.5 °C, product Tm 88.6 °C

Inputs
  • Calculate from: tm
  • Primer melting temperature: 65.5
  • Primer Tm unit: C
  • Product (target) melting temperature: 88.6
  • Product Tm unit: C

Ta = 0.3 × 65.5 + 0.7 × 88.6 − 14.9 = 19.65 + 62.02 − 14.9 = 66.77 °C (152.19 °F, 339.92 K). That is just above the usual 50–65 °C window, so a gradient around 62–68 °C would be a sensible first experiment.

Sources & references

Frequently asked questions

What is the annealing temperature in PCR?
It is the temperature of the second step of each PCR cycle, after denaturation, at which the primers bind to their complementary sites on the single-stranded template. It is usually 50–65 °C and held for 15–60 seconds before the extension step at about 72 °C.
How do I calculate the annealing temperature from primer Tm?
Use Ta = 0.3 × Tm of the less stable primer + 0.7 × Tm of the product − 14.9, with all temperatures in °C. For example, a primer Tm of 60 °C and a product Tm of 85 °C give 0.3 × 60 + 0.7 × 85 − 14.9 = 62.6 °C. A quick alternative rule is to start about 3–5 °C below the lower primer Tm.
What happens if the annealing temperature is too high or too low?
Too low and the primers tolerate mismatches, so they bind to similar sequences elsewhere and you get extra bands or primer dimers. Too high and the primers barely stay bound, so the yield drops or no product forms at all.
Why do different Tm calculators give different results for the same primer?
They use different models and default conditions. Simple GC-count formulas ignore sequence order, while nearest-neighbour models depend on the exact neighbouring bases, the salt correction chosen and the primer concentration. Differences of 5 °C or more are common, so compare primers with the same method and settings.
How far apart should the Tm values of my two primers be?
Ideally within 2–5 °C of each other. If one primer melts much lower, an annealing temperature that suits it lets the other primer bind non-specifically; this calculator warns when the gap exceeds 5 °C.

Related calculators

DNA Copy Number Calculator Converts a DNA or RNA concentration into the number of template molecules per microlitre, or a mass of DNA into a total number of copies. Enter the concentration (or mass), the template length and whether the template is double-stranded DNA, single-stranded DNA or RNA; the calculator applies Avogadro's constant and the average mass per base pair. An optional dilution helper tells you how much stock and water to mix for a target copies/µL, and the PCR section estimates copies after a number of cycles, or the cycles needed to reach a target, at any amplification efficiency. qPCR Efficiency Calculator Finds the amplification efficiency of a real-time (quantitative) PCR assay. Enter the slope of your standard curve, or paste the Ct values of a serial dilution and let the calculator fit the line and report R². It works in reverse too: turn an efficiency or amplification factor back into the expected slope. Results show the efficiency in percent, the amplification factor per cycle and whether the assay falls in the usual 90–110% window. Ligation Calculator Works out how much insert DNA to add to a ligation for a chosen insert:vector molar ratio, or how much vector goes with a given amount of insert. Enter the insert and vector lengths in bp or kb, the mass you already have, and a ratio such as the common 3:1. The calculator scales the mass by the length ratio, shows the moles of each fragment, the total DNA in the reaction and, if you enter the stock concentrations, the volume of each to pipette. DNA Concentration Calculator Turns a UV spectrophotometer reading into a nucleic acid concentration. Enter the absorbance at 260 nm, the cuvette path length and any dilution factor, and pick double-stranded DNA (50 µg/mL per A₂₆₀), single-stranded DNA (33), RNA (40), your own conversion factor, or a custom oligonucleotide. For an oligo, paste its sequence and the calculator works out the molecular weight and the nearest-neighbour extinction coefficient, or type both values in. Optional A₂₈₀ and A₂₃₀ readings give the purity ratios, and a sample volume gives the total yield. Molarity Calculator Calculates the molarity of a solution, or works backwards to the mass of solute or the volume of solution you need for a target molarity. Molarity is the amount of dissolved substance in moles per litre of solution (mol/L, written M). Enter the molar mass with the mass of solute and the final volume, a target molarity, or a mass concentration in g/L, and get the molarity, moles of solute and concentration.