DNA Copy Number Calculator

Template
Base pairs for dsDNA, bases (nucleotides) for single strands. For genomic DNA use the genome size.
Dilute to a target (optional)
copies/µL
Optional. For example 2000000 for 2 × 10⁶ copies/µL.
µL
Biology Updated 29 Oct 2026

Converts a DNA or RNA concentration into the number of template molecules per microlitre, or a mass of DNA into a total number of copies. Enter the concentration (or mass), the template length and whether the template is double-stranded DNA, single-stranded DNA or RNA; the calculator applies Avogadro's constant and the average mass per base pair. An optional dilution helper tells you how much stock and water to mix for a target copies/µL, and the PCR section estimates copies after a number of cycles, or the cycles needed to reach a target, at any amplification efficiency.

  • The concentration or mass refers only to the template of interest; contaminating DNA, RNA or free nucleotides are not removed.
  • Average masses per base (660, 330, 340 g/mol) ignore sequence composition and counter-ions.
  • PCR growth is exponential at a constant efficiency, without a plateau phase.

Formula

Copies/µL = C (ng/µL) × Nₐ ÷ (L × 10⁹ × w). Total copies = m (ng) × Nₐ ÷ (L × 10⁹ × w). PCR: N = N₀ × (1 + E)ⁿ; cycles to reach a target = log(N ÷ N₀) ÷ log(1 + E)
  • C is the concentration in ng/µL, Nₐ = 6.02214076 × 10²³ mol⁻¹ is Avogadro's constant, L is the template length in bp (or nt) and w the average molar mass of one base pair or base: 660 g/mol for dsDNA, 330 g/mol for ssDNA and 340 g/mol for RNA, the averages given by Thermo Fisher.
  • The 10⁹ converts nanograms to grams. L × w is the molar mass of one template molecule, so the formula is simply mass ÷ molar mass × Nₐ.
  • For genomic DNA, L is the haploid genome size, so the result is genome copies (and, for a single-copy gene, gene copies).
  • Dilution: stock volume = target ÷ stock concentration × final volume; the rest is water or buffer (C₁V₁ = C₂V₂).
  • PCR: with efficiency E (1.0 = 100%), each cycle multiplies the copies by 1 + E. At 100% this is the simple 2ⁿ formula. The cycles needed are rounded up to a whole cycle.
  • Molar concentration = C ÷ (L × w); amount in moles = mass ÷ (L × w).

Bacterial genome DNA at 150 ng/µL, 4.7 Mb, diluted to 2 × 10⁶ copies/µL

Inputs
  • Calculate: concentration
  • DNA concentration: 150
  • Concentration unit: ngul
  • Template length: 4.7
  • Length unit: mb
  • Template type (average mass per base): dsdna
  • Target concentration: 2000000 copies/µL
  • Final volume: 10 µL
  • Initial copies: 140000
  • Number of PCR cycles: 10
  • Amplification efficiency: 100 %

Copies/µL = 150 × 6.022 × 10²³ ÷ (4,700,000 × 10⁹ × 660) ≈ 2.912 × 10⁷ copies/µL. To make 10 µL at 2 × 10⁶ copies/µL you need 2 × 10⁶ ÷ 2.912 × 10⁷ × 10 = 0.687 µL of stock and 9.31 µL of water, about a 1:14.6 dilution. Because that is under a microlitre, an intermediate 1:10 dilution makes pipetting more accurate.

Sources & references

Frequently asked questions

Why is 660 g/mol used per base pair?
It is a convenient average for one base pair of double-stranded DNA as the sodium salt. Single strands are about half that (330 g/mol per nucleotide for DNA, 340 g/mol for RNA). Exact values depend on sequence and counter-ion (about 618 g/mol per bp without sodium), so choose 'Custom value' if you need a more precise figure.
How do I calculate gene copies from genomic DNA?
Use the haploid genome size as the template length. For example, the human haploid genome is about 3.1 × 10⁹ bp, so 1 ng contains roughly 300 genome copies, and therefore about 300 copies of a single-copy gene.
How do I make a qPCR standard curve from a plasmid?
Work out copies/µL of the purified plasmid using its full length (vector plus insert), then use the dilution helper to make the top standard (for example 10⁷ copies/µL) and serial 1:10 dilutions from it. Linearised plasmid gives more consistent standards than supercoiled DNA.
Does the PCR section give realistic yields?
It shows ideal exponential growth. Real reactions run below 100% efficiency and level off once primers, nucleotides or polymerase run short, usually well before 40 cycles. Use the efficiency field to model a measured efficiency, but treat late-cycle numbers as an upper limit.
Can I use this for RNA?
Yes. Choose single-stranded RNA (340 g/mol per nucleotide) and enter the transcript length in nucleotides. For cDNA made from that RNA, use single-stranded DNA for the first strand and double-stranded DNA after second-strand synthesis or PCR.

Related calculators

DNA Concentration Calculator Turns a UV spectrophotometer reading into a nucleic acid concentration. Enter the absorbance at 260 nm, the cuvette path length and any dilution factor, and pick double-stranded DNA (50 µg/mL per A₂₆₀), single-stranded DNA (33), RNA (40), your own conversion factor, or a custom oligonucleotide. For an oligo, paste its sequence and the calculator works out the molecular weight and the nearest-neighbour extinction coefficient, or type both values in. Optional A₂₈₀ and A₂₃₀ readings give the purity ratios, and a sample volume gives the total yield. qPCR Efficiency Calculator Finds the amplification efficiency of a real-time (quantitative) PCR assay. Enter the slope of your standard curve, or paste the Ct values of a serial dilution and let the calculator fit the line and report R². It works in reverse too: turn an efficiency or amplification factor back into the expected slope. Results show the efficiency in percent, the amplification factor per cycle and whether the assay falls in the usual 90–110% window. Ligation Calculator Works out how much insert DNA to add to a ligation for a chosen insert:vector molar ratio, or how much vector goes with a given amount of insert. Enter the insert and vector lengths in bp or kb, the mass you already have, and a ratio such as the common 3:1. The calculator scales the mass by the length ratio, shows the moles of each fragment, the total DNA in the reaction and, if you enter the stock concentrations, the volume of each to pipette. Annealing Temperature Calculator Finds the optimal PCR annealing temperature with the Rychlik formula Ta = 0.3 × Tm(primer) + 0.7 × Tm(product) − 14.9. Enter the melting temperature of the less stable primer and of the PCR product in °C, °F or K, or paste both primer sequences and let the calculator work out each primer's Tm (nearest-neighbour, salt-adjusted or basic method) and the product Tm from its length and GC content at your salt concentration. It also flags primer pairs whose melting temperatures differ by more than 5 °C. Cell Dilution Calculator Plan a cell suspension dilution with C1 × V1 = C2 × V2. Enter any three of the stock concentration, the volume of stock to take, the target concentration and the final volume, each with its own unit (µL, mL, cL or L), and the calculator finds the fourth. It also reports the dilution factor, how much medium or buffer to add, the total number of cells, and a serial dilution plan when the stock volume is too small to pipette accurately.